Cat Oil and Gas Engines ● Power and Production

Engines

CM Pump Application Emissions according toWB2

Crude Oil/ Heavy Fuel Operation at COP

Minimum Speed

Output Range Speed

Bore x Stroke

Fuel Efficiency

4

CM Model

FuelType

kW hp

rpm rpm mm in

g/kWh MJ/kWh

Diesel Diesel Diesel Diesel Diesel Diesel Diesel Diesel Diesel

1140 1520 1710 1800 2400 2700 2700 3600 4050

1000 1000 1000

300 300 300 250 240 250 360 360 360

200 x 300 200 x 300 200 x 300 250 x 400 250 x 400 250 x 400 320 x 480 320 x 480 320 x 480

190 190 190 185 185 185 185 185 185

8.11 8.11 8.11 7.90 7.90 7.90 7.90 7.90 7.90

x x x x x x x x x

6CM20C 8CM20C 9CM20C 6CM25C 8CM25C 9CM25C 6CM32C 8CM32C 9CM32C

1529 2038 2293 2414 3218 3621 3621 4828 5431

7.9 x 11.8 7.9 x 11.8 7.9 x 11.8 9.8 x 15.7 9.8 x 15.7 9.8 x 15.7 12.6 x 18.9 12.6 x 18.9 12.6 x 18.9

750 750 750 600 600 600

Gas Engines: G12CM34

Natural gas 4575 Natural gas 6100

750 750

450 450

340 x 420 340 x 420

N/A 7.92 N/A 7.94

6135 8180

13.4 x 16.5 13.4 x 16.5

G16CM34

*Heat rate (MJ/kWh) for gaseous fuel.

NOTES: • Ratings: Continuous power based on ISO 3046-1 standard reference conditions. • Power output: May require adjustment for values other than ISO 3046-1 standard reference conditions.

• Fuel as specified per ISO 8217. Limiting Caterpillar specification for fuel is VD8738 for crude oil operation at continuous power operation (COP). • Fuel consumption: Based on ISO 3046-1 standard reference conditions of 25° C (77° F) and 100 kPa (29.61 in Hg) , including one engine-driven lube oil pump, with 5% tolerance and LCV = 42 700 kJ/kg (18,358 Btu/lb) . • Dual Fuel (DF) engines: Specific fuel consumption (g/kWh) for liquid fuel; heat rate MJ/kWh for gaseous fuel. • Generator efficiency: Efficiency of 97.0% (96.0% for complete CM20 and CM25 model range, and for 6CM32, 8CM32, 9CM32) based on power factor 0.8 with medium voltage class generator; actual efficiency will depend on generator selection. • Crude oil operation only at continuous power generation.

Edition 47 4-35